04.09.10.01 04.09.10.01 KAWEFLEX® 6110 TRAY SK-PVC UL/CSA
Application
As highly flexible connection and control cable for high electrical and normal mechanical requirements in cable drag chains and motion drive systems in machine and plant construction.
TC-ER and MTW approvals enable open wiring on cable trays as well as the usage for industrial machines with only one cable
Special Features
- UL/CSA approval
- low adhesion, silicone-free
- increased oil-resistant special PVC outer sheath, largely resistant to greases, coolants and lubricants acids and alkalis - oil-resistant according to UL OIL RES I
- water resistant according to UL wet approval 75°C
- Flame retardant acc. to IEC 60332-1-2, CSA FT4, UL Vertical Tray Flame Test
- UV-resistant
Remarks
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- acc. to NFPA 79 and NEC "National Electrical Code" Art. 336, 392, 501
Structure & Specifications
conductor_material
bare copper strand
conductor_class
acc. to IEC 60228 cl. 6
insulation_material
PVC
wire_identification
acc. to DIN VDE 0293 black cores with white numerals; G = GNYE
twisting_total
cores stranded in layers
outersheath_material
PVC
sheath_color
black RAL 9005
voltage_nominal
IEC: 300/500 V; UL/CSA: 600V (TC, MTW, CIC), 1.000V (WTTC, AWM)
voltage_test
6 kV
resistance_conductor
at +20 °C acc. to IEC 60228 cl. 6
resistance_isolation
at +20 °C ≥ 20 MΩ x km
carrying_capacity
acc. to DIN VDE
bending_radius_smallest_fixed
4 x d
bending_radius_smallest_moving
7,5 x d < 10m TL | 10 x d ≥ 10m TL
operating_temperature_fixed
-40 °C / +90 °C
operating_temperature_moving
-5 °C / +90 °C
fire_behaviour
flame-retardant acc. to IEC 60332-1, IEC 60332-3A, UL: Vertical-Tray Flame Test, CSA; FT4
oil_resistance
UL 1277 and UL 1063 (oil-resistant acc. to UL OIL RES I and water-resistant, UL wet approval 75 °C)
standard
UL 1277, UL 1063 (MTW), NEC 336.10 (7) class1, Div. 2 acc. NEC Art. 336, 392, 501
approbation
UL/CSA - cULus & cURus 1.000V, 90°C (AWM, WTTC) and cULus & cURus 600V, 90°C (TC-ER, MTW, CIC)
traversing_speed
self-supporting: max. 5 m/s; gliding: max. 2,5 m/s
traversing_way
max. 25 m
acceleration
max. 10 m/s²
bending_cycles
> 5 Mio.

Application
As highly flexible connection and control cable for high electrical and normal mechanical requirements in cable drag chains and motion drive systems in machine and plant construction. TC-ER and MTW approvals enable open wiring on cable trays as well as the usage for industrial machines with only one cable
Special Features
- UL/CSA approval
- low adhesion, silicone-free
- increased oil-resistant special PVC outer sheath, largely resistant to greases, coolants and lubricants acids and alkalis - oil-resistant according to UL OIL RES I
- water resistant according to UL wet approval 75°C
- Flame retardant acc. to IEC 60332-1-2, CSA FT4, UL Vertical Tray Flame Test
- UV-resistant
Remarks
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- acc. to NFPA 79 and NEC "National Electrical Code" Art. 336, 392, 501
Structure & Specifications
conductor_material | bare copper strand |
---|---|
conductor_class | acc. to IEC 60228 cl. 6 |
insulation_material | PVC |
wire_identification | acc. to DIN VDE 0293 black cores with white numerals; G = GNYE |
twisting_total | cores stranded in layers |
outersheath_material | PVC |
sheath_color | black RAL 9005 |
voltage_nominal | IEC: 300/500 V; UL/CSA: 600V (TC, MTW, CIC), 1.000V (WTTC, AWM) |
voltage_test | 6 kV |
resistance_conductor | at +20 °C acc. to IEC 60228 cl. 6 |
resistance_isolation | at +20 °C ≥ 20 MΩ x km |
carrying_capacity | acc. to DIN VDE |
bending_radius_smallest_fixed | 4 x d |
bending_radius_smallest_moving | 7,5 x d < 10m TL | 10 x d ≥ 10m TL |
operating_temperature_fixed | -40 °C / +90 °C |
operating_temperature_moving | -5 °C / +90 °C |
fire_behaviour | flame-retardant acc. to IEC 60332-1, IEC 60332-3A, UL: Vertical-Tray Flame Test, CSA; FT4 |
oil_resistance | UL 1277 and UL 1063 (oil-resistant acc. to UL OIL RES I and water-resistant, UL wet approval 75 °C) |
standard | UL 1277, UL 1063 (MTW), NEC 336.10 (7) class1, Div. 2 acc. NEC Art. 336, 392, 501 |
approbation | UL/CSA - cULus & cURus 1.000V, 90°C (AWM, WTTC) and cULus & cURus 600V, 90°C (TC-ER, MTW, CIC) |
traversing_speed | self-supporting: max. 5 m/s; gliding: max. 2,5 m/s |
traversing_way | max. 25 m |
acceleration | max. 10 m/s² |
bending_cycles | > 5 Mio. |