04.09.25.01 KAWEFLEX® 6210 TRAY SK-C-PVC UL/CSA
Application
As shielded highly flexible connection and control cable for high electrical and normal mechanical requirements in cable drag chains and motion drive systems in machine and plant construction.
TC-ER and MTW approvals enable open wiring on cable trays as well as the usage for industrial machines with only one cable
Special Features
- UL/CSA approval
- low adhesion, silicone-free
- increased oil-resistant special PVC outer sheath, largely resistant to greases, coolants and lubricants acids and alkalis - oil-resistant according to UL OIL RES I
- water resistant according to UL wet approval 75°C
- Flame retardant acc. to IEC 60332-1-2, CSA FT4, UL Vertical Tray Flame Test
- UV-resistant
- recommended for EMC-applications
Remarks
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- acc. to NFPA 79 and NEC "National Electrical Code" Art. 336, 392, 501
Structure & Specifications
conductor_material
bare copper strand
conductor_class
acc. to IEC 60228 cl. 6
insulation_material
PVC
wire_identification
acc. to DIN VDE 0293 black cores with white numerals; G = GNYE
shielding_total
copper braid tinned; coverage ca. 85 %
twisting_total
cores stranded in layers
outersheath_material
PVC
sheath_color
black RAL 9005
voltage_nominal
IEC: 300/500 V; UL/CSA: 600V (TC, MTW, CIC), 1.000V (WTTC, AWM)
voltage_test
6 kV
resistance_conductor
at +20 °C acc. to IEC 60228 cl. 6
resistance_isolation
at +20 °C ≥ 20 MΩ x km
carrying_capacity
acc. to DIN VDE
bending_radius_smallest_fixed
4 x d
bending_radius_smallest_moving
7,5 x d < 10m TL | 10 x d ≥ 10m TL
operating_temperature_fixed
-40 °C / +90 °C
operating_temperature_moving
-5 °C / +90 °C
fire_behaviour
flame-retardant acc. to IEC 60332-1, IEC 60332-3A, UL: Vertical-Tray Flame Test, CSA; FT4
oil_resistance
UL 1277 and UL 1063 (oil-resistant acc. to UL OIL RES I and water-resistant, UL wet approval 75 °C)
standard
UL 1277, UL 1063 (MTW), NEC 336.10 (7) class1, Div. 2 acc. NEC Art. 336, 392, 501
approbation
UL/CSA - cULus & cURus 1.000V, 90°C (AWM, WTTC) and cULus & cURus 600V, 90°C (TC-ER, MTW, CIC)
traversing_speed
self-supporting: max. 5 m/s; gliding: max. 2,5 m/s
traversing_way
max. 25 m
acceleration
max. 10 m/s²
bending_cycles
> 5 Mio.

Application
As shielded highly flexible connection and control cable for high electrical and normal mechanical requirements in cable drag chains and motion drive systems in machine and plant construction. TC-ER and MTW approvals enable open wiring on cable trays as well as the usage for industrial machines with only one cable
Special Features
- UL/CSA approval
- low adhesion, silicone-free
- increased oil-resistant special PVC outer sheath, largely resistant to greases, coolants and lubricants acids and alkalis - oil-resistant according to UL OIL RES I
- water resistant according to UL wet approval 75°C
- Flame retardant acc. to IEC 60332-1-2, CSA FT4, UL Vertical Tray Flame Test
- UV-resistant
- recommended for EMC-applications
Remarks
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- acc. to NFPA 79 and NEC "National Electrical Code" Art. 336, 392, 501
Structure & Specifications
conductor_material | bare copper strand |
---|---|
conductor_class | acc. to IEC 60228 cl. 6 |
insulation_material | PVC |
wire_identification | acc. to DIN VDE 0293 black cores with white numerals; G = GNYE |
shielding_total | copper braid tinned; coverage ca. 85 % |
twisting_total | cores stranded in layers |
outersheath_material | PVC |
sheath_color | black RAL 9005 |
voltage_nominal | IEC: 300/500 V; UL/CSA: 600V (TC, MTW, CIC), 1.000V (WTTC, AWM) |
voltage_test | 6 kV |
resistance_conductor | at +20 °C acc. to IEC 60228 cl. 6 |
resistance_isolation | at +20 °C ≥ 20 MΩ x km |
carrying_capacity | acc. to DIN VDE |
bending_radius_smallest_fixed | 4 x d |
bending_radius_smallest_moving | 7,5 x d < 10m TL | 10 x d ≥ 10m TL |
operating_temperature_fixed | -40 °C / +90 °C |
operating_temperature_moving | -5 °C / +90 °C |
fire_behaviour | flame-retardant acc. to IEC 60332-1, IEC 60332-3A, UL: Vertical-Tray Flame Test, CSA; FT4 |
oil_resistance | UL 1277 and UL 1063 (oil-resistant acc. to UL OIL RES I and water-resistant, UL wet approval 75 °C) |
standard | UL 1277, UL 1063 (MTW), NEC 336.10 (7) class1, Div. 2 acc. NEC Art. 336, 392, 501 |
approbation | UL/CSA - cULus & cURus 1.000V, 90°C (AWM, WTTC) and cULus & cURus 600V, 90°C (TC-ER, MTW, CIC) |
traversing_speed | self-supporting: max. 5 m/s; gliding: max. 2,5 m/s |
traversing_way | max. 25 m |
acceleration | max. 10 m/s² |
bending_cycles | > 5 Mio. |