04.09.25 KAWEFLEX® 6210 SK-C-PVC UL/CSA

Application

As highly flexible, shielded power and control cable for EMC-compliant connecting at high electrical and normal mechanical requirements in drag chains and motion drive systems in machine and plant engineering.

Special Features

  • UL/CSA approved
  • low adhesion, silicone-free
  • flame-retardant acc. to IEC 60332-1-2, FT1, VW-1
  • oilresistant acc. to DIN EN 60811-404 (only mineral oil)
  • largely resistant to grease, coolant fluids and lubricants
  • recommended for EMC-compatible applications
  • due to 600 V UL/CSA approval parallel laying with other 600 V cables is permitted

Remarks

  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Structure & Specifications

conductor_material bare copper strand
conductor_class acc. to DIN VDE 0295 class 6 pt. 4 resp. IEC 60228 cl. 6 pt. 4
insulation_material PVC
wire_identification acc. to DIN VDE 0293 black wires with white numerals, 1 x GNYE
shielding_total copper braid tinned, coverage approx. 85%
twisting_total cores stranded in layers
outersheath_material PVC
sheath_color grey RAL 7001
voltage_nominal acc. to IEC: 300/500 V; acc. to UL: 600 V
voltage_test core/core: 4 kV, core/shield: 2 kV
resistance_conductor at +20 °C acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6
resistance_isolation at +20 °C ≥ 20 MΩ x km
carrying_capacity acc. to DIN VDE
bending_radius_smallest_fixed 4 x d
bending_radius_smallest_moving 7,5 x d < 10m TL | 10 x d ≥ 10m TL
operating_temperature_fixed -40 °C / +90 °C
operating_temperature_moving -5 °C / +90 °C
fire_behaviour flame-retardant acc. to IEC 60332-1-2, FT1, VW-1
approbation UL/CSA - cURus 600V, 90°C
traversing_speed self-supporting: max. 5 m/s, gliding: max. 2,5 m/s
traversing_way max. 25 m
acceleration max. 10 m/s²