02.05.02 DATEX-PiMf-CY Li2YCY-PiMf

Application

Data transmission cable, control and connecting cable especially for cabling with high data transfer rates up to 10 Mb/s, for lossless data and signal transmission. For fixed laying and flexible applications with undefined cable routing and without tensile stress. Suitable for use in dry and humid rooms. Outdoor use only with UV-protection, no laying underground.

Special Features

  • shielded single pairs by aluminium foil-clad
  • twisted pairs
  • largely resistant to acids, bases and specified types of oil
  • LABS-/silicone-free (during production)
  • recommended for EMC-applications
  • suitable for maxi-termi-point applications by 7wire conductors <1 mm²

Remarks

  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Structure & Specifications

conductor_material bare copper strand
conductor_class 7 wired
insulation_material PE
wire_identification acc. to DIN 47100 different colours
twisting pairs stranded in layers
shielding pairs in metal-foil (PiMf) with subjacent tinned drain wire
shielding_total copper braid tinned; coverage approx. 85%
outersheath_material PVC
sheath_color grey, RAL 7032
voltage_nominal 250 V
voltage_test core/core: 2 kV; core/shield: 1 kV
resistance_conductor loop: 0,22 mm² max. 186 Ω / km; 0,34 mm² max. 115 Ω / km; 0,50 mm² max. 78,4 Ω / km
resistance_isolation min 5 GΩ x km
carrying_capacity acc. to DIN VDE, s. Techn. Guidelines
capacity up to 0,34 max. 70 nF/km; 0,5 mm² max. 75nF/km; 1,0 mm² max. 84nF/km (from 4 pairs)
bending_radius_smallest_fixed 10 x d
bending_radius_smallest_moving 15 x d
operating_temperature_fixed -30 °C / +80 °C
operating_temperature_moving -5 °C / +70 °C
fire_behaviour flame-retardant acc. to IEC 60332-1-2
standard similar to DIN VDE 0812

Downlaod Datasheet Download certificate