08.05.01 THERM-205-FEP-EA

Application

Heat and coldness resistant single core for use where warmness and coldness directly act on cables

Special Features

  • high resistance to chemicals and dissolvers
  • nearly frequency independent dielectric characteristics
  • flame-retardant
  • high breakdown strength and high abrasion resistance
  • high elongation and high tear strength
  • FEP is resistant to ozone, oxygene, sea water and weather-proofed

Remarks

  • conform to RoHS
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Structure & Specifications

conductor material copper strand tinned or silvered
conductor class fine-stranded similar to IEC 60228 see table right side
core material FEP
core identification different colours
rated voltage Typ KT: 250 V; Typ K: 600 V; Typ KK: 1 kV
testing voltage Typ KT: 2,5 kV; Typ K: 3,4 kV; Typ KK: 5 kV
resistance_conductor at +20 °C acc. to IEC 60228 cl. 5
resistance_isolation min. 1,5 GΩ x km
current carrying capacity acc. to DIN VDE, see Technical Guidelines
min. bending radius fixed 4 x d
min. bending radius moved 10 x d
operat. temp. fixed min/max -100 °C / +205 °C; short-time: +230 °C (when using adequate conductor materials)
temp. at conductor Cu-vz: +180 °C; Cu-vs: +200 °C
burning behavior self-extinguishing & flame-retardant acc.to IEC 60332-1-2