Shielded, low capacity power cable, also with 2, 3 resp. 4 control cores for temperature sensors or brake for EMC-compatible connecting between drives and frequency converter for high requirements in drag chain applications, moving drive systems, in the field of robotic technology, in manufacturing plants as well as in dry and humid rooms.
Special Features
conform to DESINA, UL/CSA approved
flame-retardant, UV-resistant, halogen-free, low adhesion and low abrasion
largely resistant to grease, coolant fluids and lubricants
resistant to oil acc. to DIN EN 60811-404
silicone-free
CFC-free nach DIN 472815/IEC 60754-1
Remarks
conform to RoHS
conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
very long lifetime, optimal cost-value ratio
platz- und gewichtssparend
We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Structure & Specifications
conductor material
bare copper strand
conductor class
acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6
core material
PELON®2
core identification
supply cores: BK with WH print U/L1/C/L+; V/L2; W/L3/D/L- and GNYE; control cores: 1-pair, BK and WH; 2-pair: BK with WH print 5, 6, 7, 8; triple: bk with wh numerals 1. 2, 3
shield
control pairs resp. triple with tinned copper shield
shield
copper braid tinned, opt. coverage appr. 85 %
overall stranding
all cores and elements stranded together with high flexible fillers
outer sheath
PUR, halogen-free, flame retardant
sheath colour
orange, RAL 2003
rated voltage
Uo/U 600/1.000 V; UL & CSA: 1.000 V
testing voltage
4 kV
resistance_conductor
at +20 °C acc. to DIN VDE 0295 cl. 6/IEC 60228 cl. 6
resistance_isolation
at +20 °C ≥ 20 GΩ x km
min. bending radius fixed
4 x d - after installation
min. bending radius moved
7,5 x D (≤ 16 mm²) / 10 x D (≥ 25 mm²)
operat. temp. fixed min/max
-50 °C / +80 °C
operat. temp. moved min/max
-40 °C / +80 °C
burning behavior
sebstverlöschend und flammwidrig nach IEC 60332-1-2
approbation
UL/CSA - cURus 1.000 V, 80 °C
speed
max. 300 m/min
traverse length
horiz.: ≤ 16mm² max. 50 m / ≥ 25mm² max. 20 m; vertical: max. 5 m