03.10.05.01 FOUNDATION™ Fieldbus 100 Ω UL/CSA
Application
As fieldbus cable for FOUNDATION™ Fieldbus systems, specifically for use in process automation as well as in hazardous areas to connect sensors and actuators,for fixed installation & limited flexible applications.
Standard acc.to FOUNDATION™ Fieldbus recommend. for Type A cables & EN61158
Special Features
- largely resistant to lubricants, coolants fluids and grease
- oil-resistant: acc.to DIN EN 60811-2-1 (only mineral oil)
- UV-resistant
- optimized EMC compliant shielding
Remarks
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- Type Ex - blue outer sheath: for applications in hazardous areas
Structure & Specifications
conductor material
bare copper strand
conductor class
7-wired
core material
Polyolefin or foamed polyolefin
core identification
orange, blue
shield
(St)-PVC: alu-lamin. polyester foil with subjacent tinned drain wire | (St)C-PVC: alu-lamin. polyester foil, copper braid tinned with subjacent tinned drain
outer sheath
PVC
sheath colour
blue RAL 5015 (BU) or orange RAL 2003 (OR)
rated voltage
300 V (not for high voltage purposes)
testing voltage
1,5 kV
resistance_loop
max. 43,8 Ohm/km
capacity
max. 60 nF/km
surge_impedance
100 Ω
transfer size
max. 1.900 m
min. bending radius fixed
5 x d
min. bending radius moved
10 x d
operat. temp. fixed min/max
- 40 °C / +80 °C
operat. temp. moved min/max
- 10 °C / +70 °C
burning behavior
flame retardant acc. to IEC 60332-3-24 (Cat. C), FT4
oil_resistance
acc. to DIN EN 60811-2-1 (only mineral oil)
approbation
UL/CSA - cULus 300V, 75°C, CM/PLTC/SunRes/OilRes & (St)C-PVC additional cURus 600V, 60°C

Application
As fieldbus cable for FOUNDATION™ Fieldbus systems, specifically for use in process automation as well as in hazardous areas to connect sensors and actuators,for fixed installation & limited flexible applications. Standard acc.to FOUNDATION™ Fieldbus recommend. for Type A cables & EN61158
Special Features
- largely resistant to lubricants, coolants fluids and grease
- oil-resistant: acc.to DIN EN 60811-2-1 (only mineral oil)
- UV-resistant
- optimized EMC compliant shielding
Remarks
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- Type Ex - blue outer sheath: for applications in hazardous areas
Structure & Specifications
conductor material | bare copper strand |
---|---|
conductor class | 7-wired |
core material | Polyolefin or foamed polyolefin |
core identification | orange, blue |
shield | (St)-PVC: alu-lamin. polyester foil with subjacent tinned drain wire | (St)C-PVC: alu-lamin. polyester foil, copper braid tinned with subjacent tinned drain |
outer sheath | PVC |
sheath colour | blue RAL 5015 (BU) or orange RAL 2003 (OR) |
rated voltage | 300 V (not for high voltage purposes) |
testing voltage | 1,5 kV |
resistance_loop | max. 43,8 Ohm/km |
capacity | max. 60 nF/km |
surge_impedance | 100 Ω |
transfer size | max. 1.900 m |
min. bending radius fixed | 5 x d |
min. bending radius moved | 10 x d |
operat. temp. fixed min/max | - 40 °C / +80 °C |
operat. temp. moved min/max | - 10 °C / +70 °C |
burning behavior | flame retardant acc. to IEC 60332-3-24 (Cat. C), FT4 |
oil_resistance | acc. to DIN EN 60811-2-1 (only mineral oil) |
approbation | UL/CSA - cULus 300V, 75°C, CM/PLTC/SunRes/OilRes & (St)C-PVC additional cURus 600V, 60°C |