02.06.03 RD-Y(St)Y Bd

Application

Installation cable, data transmission cable, control and connecting cable in telecommunication and IT-systems as well as in measurement and control technology for lossless data and signal transmission. Suitable for use in dry and humid rooms, outdoor use only with UV-protection. No laying underground.

Special Features

  • shielded by plastic clad aluminium foil
  • pairs stranded to bundles (Bd)
  • largely resistant to acids, bases and specified types of oils
  • free from lacquer damaging substances and silicone (during production)
  • also available:
    RD-Y(St)Y Bd EB with blue outer sheath for intrinsically safe systems
    RD-Y(St)Yv Bd with strengthend outer sheath or halogenfree RD-H(St)H Bd
  • suitable for maxi-termi-point applications by 7-wire conductors

Remarks

  • conform to RoHS
  • conform to 2006/95/EC-Guideline CE
  • installation cables are not designed for high voltage purposes and are not suitablefor laying underground
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Structure & Specifications

conductor material bare copper strand
conductor class 7 wired
core material PVC
core identification acc. to VDE 0815 different colours
stranding pairs stranded to bundles
shield plastic clad aluminium foil with subjacent drain wire 0,8 mm
outer sheath PVC
sheath colour grey RAL7000
rated voltage 225 V
testing voltage core/core: 2 kV; core/shield: 2 kV
conductor resistance loop: 0,5: max 78,4 Ω / km; 1,0: max 36,8 Ω / km
insulation resistance min 100 MΩ x km
current carrying capacity acc. to DIN VDE, s. Techn. Guidelines
capacity max. 100 nF/km
min. bending radius fixed 7,5 x d
min. bending radius moved 10 x d
operat. temp. fixed min/max -30 °C / +70 °C
operat. temp. moved min/max - 5 °C / +50 °C
burning behavior acc. to VDE 0472-804-B und IEC 60332-1
standard acc. to DIN VDE 0815

Download datasheet